The latest in combustion analysis technology
Compact, Light and Durable Design
•Ergonomic, light weight, & durable design
•Data management with automatic logging & report creation
•Predictive maintenance with estimated sensor life & calibration reminders
•One touch pump On/Off with purge
•PC software with wireless and USB connectivity
•Auto pump cut-off for high CO levels
•Graphical data display
•Customisable gas analysis screen
•Sample conditioning unit for low NOx & high moisture applications
•Stack gas velocity with Pitot tube
•Draft & differential pressure measurements
•Emissions values adjusted for reference O2
•CO & CO2 Monitoring in Ambient Air
•Hose extensions for tall & difficult to reach stacks
•Wireless Printer
•Protective rubber holster
•Maintenance contracts and extended warranties available
Download datasheet : Sauermann Si-CA 230 Combustion Analyzer
The latest in combustion analysis technology
Compact, Light and Durable Design
•Ergonomic, light weight, & durable design
•Data management with automatic logging & report creation
•Predictive maintenance with estimated sensor life & calibration reminders
•One touch pump On/Off with purge
•PC software with wireless and USB connectivity
•Auto pump cut-off for high CO levels
•Graphical data display
•Customisable gas analysis screen
•Sample conditioning unit for low NOx & high moisture applications
•Stack gas velocity with Pitot tube
•Draft & differential pressure measurements
•Emissions values adjusted for reference O2
•CO & CO2 Monitoring in Ambient Air
•Hose extensions for tall & difficult to reach stacks
•Wireless Printer
•Protective rubber holster
•Maintenance contracts and extended warranties available
Download datasheet : Sauermann Si-CA 230 Combustion Analyzer
Technical specifications
| Parameter | Sensor | Measuring range | Resolution | Accuracy(1) | T90 response time |
| O2 | Electrochemical | 0 to 25% | 0.01% | ±0.2% vol | T90 < 30 s |
| CO (H2 comp.) | Electrochemical | 0 to 8000 ppm | 1 ppm | ±8 ppm < 160 ppm ±5% rdg up to 2000 ppm ±10% rdg > 2000 ppm |
T90 < 40 s |
| CO (with dilution) | Electrochemical | 100 to 50,000 ppm | 1 ppm | ±10% rdg | T90 < 40 s |
| CO2 | Calculated | 0 to 99.9% | 0.1% | – | – |
| NO | Electrochemical | 0 to 5000 ppm | 1 ppm | ±5 ppm < 100 ppm ±5% rdg > 100 ppm |
T90 < 40 s |
| Low NO | Electrochemical | 0 to 300 ppm | 0.1 ppm | ±1.5 ppm < 30 ppm ±5 % rdg > 30 ppm |
T90 < 40 s |
| NO2 | Electrochemical | 0 to 1000 ppm | 1 ppm | ±5 ppm < 100 ppm ±5 % rdg > 100 ppm |
T60 < 60 s |
| Low NO2 | Electrochemical | 0 to 100 ppm | 0.1 ppm | ±1.5 ppm < 30 ppm ±5% rdg > 30 ppm |
T60 < 60 s |
| NOx (optional) | Calculated | 0 to 7500 ppm | 1 ppm | – |
– |
| Low NOx (optional) | Calculated | 0 to 450 ppm | 0.1 ppm | – |
– |
| SO2 | Electrochemical | 0 to 5000 ppm | 1 ppm | ±5 ppm < 100 ppm ±5% rdg > 100 ppm |
T60 < 30 s |
| Low SO2 | Electrochemical | 0 to 100 ppm | 0.1 ppm | ±1.5 ppm < 30 ppm ±5% rdg > 30 ppm |
T60 < 30 s |
| CxHy (HC) | Pellistor | 0 to 5% | 0.01% | ± 5% full scale |
T90 < 40 s |
| H2S | Electrochemical | 0 to 500 ppm | 0.1 ppm | ±5 ppm < 100 ppm ±5% rdg > 100 ppm |
T60 < 35 s |
| Flue temperature | TcK |
-20 to +1250 °C -4 to +2282 °F |
0.1 °C 0.1 °F |
±2 °C or ±0.5% rdg(2) ±3.6 °F or ±0.5% rdg(2) |
– |
| Air temperature | NTC or TcK | -20 to +120 °C -4 to +248 °F |
0.1 °C 0.1 °F |
±2 °C ±3.6 °F |
– |
| Differential temperature | Calculated | 0 to 1250 °C 0 to 2282 °F |
0.1 °C 0.1 °F |
– | – |
| Pressure/Draft | Semiconductor |
-200 to +200 mbar |
0.01 mbar 0.001 inH2O |
±1% rdg ±0.03 mbar ±1% rdg ±0.012 inH2O |
– |
| High accuracy draft | Semiconductor |
500 Pa |
0.1 Pa | ±0.5 Pa < 10 Pa ±3 Pa up to 150 Pa ±1% rdg ±1.5 Pa > 150 Pa |
– |
| Excess air | Calculated | 0 to 999% | 1% | – | – |
| Efficiency | Calculated | 0 to 100% (Gross/HHV(3)) | 0.1% | – | – |
| Efficiency (condensation) | Calculated | 0 to 125% (Net/LHV(4)) | 0.1% | – | – |
| Stack Gas velocity | Calculated | 0 to 99 m/s 0 to 19,500 fpm |
0.1 m/s 1 fpm |
– | – |
(1)All accuracies indicated in this document were stated in laboratory conditions at 20 °C (68 °F) and 1013 mbar and can be guaranteed for measurement carried out in the same conditions.
(2)Accuracy given for the analyzer only.
(3)For Higher Heating Value / (4)For Lower Heating Value
The Si-K25 and Si-K85 are airflow measurement cones designed for 100 mm diameter vane anemometers. These models feature a honeycomb-structured airflow straightener that reduces turbulence for more reliable flow measurement.
The Si-K25 and Si-K85 are perfectly suited to Kimo LV 110 and LV 130, VT 210, MP 210 and AMI 310 anemometers.
The Si-K85 square cone can be used with medium-sized air vents.
The Si-K25 round cone is designed for small and medium-sized round vents.
Airflow Cones Ø 100 mm Vane Anemometers
Download Datasheet : Airflow Cones
Learn MoreDownload Datasheet : Sauermann Si-VH3
Learn MoreConnection cable between the transmitter and:
Connection cable between the transmitter and:
Interchangeable VOC probe. Plastic body, Ø 29.5 mm, length: 175 mm. Autolock connector. Probe cable for connection to
class 320 transmitters is needed. Supplied with mounting flange and adjustment certificate.
Download Specsheet : Probe for Class320 Transmitter
Learn MoreInterchangeable CO probe. Plastic body, Ø 29.5 mm, length: 175 mm. Autolock connector. Probe cable for connection to class 320 transmitters is needed. Supplied with mounting flange and adjustment certificate.
Download Specsheet : Probe for Class320 Transmitter
Learn MoreInterchangeable CO2 probe. Plastic body, Ø 29.5 mm, length: 175 mm. Autolock connector. Probe cable connection to class 320 transmitters
is needed.. Supplied with mounting flange and adjustment certificate.
Download Specsheet : Probe for Class320 Transmitter
Learn MoreInterchangeable hotwire probe for air velocity and temperature measurements. Stainless steel body length 267 mm, Ø 8 mm. Autolock connector. Supplied with adjustment certificate.
Download Specsheet : Probe for Class320 Transmitter
Learn MoreInterchangeable Pt100 temperature probe. Stainless steel sheath, dimensions: length 153 mm, Ø 6 mm. Autolock connector. Supplied with adjustment certificate.
Download Specsheet : Probe for Class320 Transmitter
Learn MoreInterchangeable hygrometry/temperature probe. Plastic body with stainless steel filter. Length 150 mm, Ø 13 mm. Autolocking connector. Probe cable for connection to class 320 transmitters is needed. Supplied with adjustment certificate.
Download Specsheet : Probe for Class320 Transmitter
Learn More