C.A 1954 Thermal Camera .
  • UFPA microbolometer-type 160 x 120 detector, 8 ~14 μm
  • NETD: 0.08 °C
  • IFOV (spatial resolution) 4.4 mrad
  • Temperature range: -20°C to +250°C
  • Display modes: thermal image or real image with automatic parallax compensation. Image merging available with the PC software
  • Measuring tools: 1 manual cursor + 1 automatic detection cursor + Min-Max-Avg on adjustable area + temperature profile + isotherm with recovery of dew point via Bluetooth
  • Adjustable settings: emissivity, environmental temperature, distance, relative humidity
  • Memory: on 2 GB micro SD card (approx. 4,000 images) – exchangeable up to 32 GB
  • IP 54 ingress protection
  • Weight / Dimensions: 700 g with rechargeable batteries / 225x125x83
Learn More

RM11,642.00

  • Availability: 0 in stock
Compare

RM913.00

  • Availability: 0 in stock
Compare
Energy Logger PEL 103

Functional: Implementation without cutting off the power to the electrical network.

Useful: Data recording on integrated 8 GB SD card.

Universal: Compatible with all types of electrical networks: single-phase, split-phase, three -phase with or without neutral, etc.

Practical: Compact and magnetized, can be mounted in any metal cabinet.

Learn More

RM11,500.00

  • Availability: 0 in stock
Compare
CA 732 Contact-Free AC Voltage Detector with Torch Function , .

Its pen-style format with a clip means you can clip it to your pocket so it is always to hand.

Functions:

  • Phase identification: the tip of the instrument lights up in the presence of a 230 V AC – 50/60 Hz voltage
  • Torch
  • IEC 61010 1000V CAT III – Double insulation
Learn More

RM133.00

  • Availability: 0 in stock
Compare
C.A 745N

RM272.00

C.A 745N , .

With our NEW DIGITAL VOLTAGE & Ohm Ω TESTERS, we are able to perform the application mentioned below :

1. Automatic recognition of AC and DC voltage
2. No risk of tripping the high-sensitivity RCSs when testing phase/earth.
3. The removable test probes mean they can be replaced at lower cost and offer users the possibility of choosing different probes for different uses, if required.

Learn More

RM272.00

  • Availability: 0 in stock
Compare
CA 755 Digital Tester , .

The C.A 755 is rated 600V CAT III and complies with the new IEC 61010-2-033 standard on multimeters.
It offfers both the basic functions, such as voltage and continuity, and more specific multimeter functions such as diode test, resistance, continuity and capacitance. With its “SMART” function, the C.A 755 automatically recognizes DC or AC, as well as resistors, diodes and capacitors.
Simple and effective, the test probes are easy to remove and replace. They are stowed in a compartment built into the instrument.

Specifications:
•   Voltage: 3 mVDC to 1,000 VDC/ 100 mVAC to 1,000 VAC
•   Resistance: 0.3 Ω to 30 MΩ
•   Capacitance: 400 pF to 30 mF
•   Diode test
•   Audible continuity for R ≤ 30 Ω
•   600 V CAT III

Learn More

RM402.00

  • Availability: 0 in stock
Compare
CA 757 Digital Tester with MiniFlex , .

With its 600 V CAT III double insulation, the C.A 757 complies with the new IEC 61010-2-033 standard for multimeters.

Simple to use, the C.A 757 automatically recognizes Ac and DC voltages, as well as continuity, resistors, diodes and capacitors. It also detects live conductors without contact.
Lastly, the C.A 757 is delivered with a MiniFlex flexible current sensor allowing current measurements up to 300 AAC even in places where access is difficult.

Main specifications:

•   DC voltage: 3 mVDC to 1000 VDC
•   AC voltage: 100 mVAC to 1000 VAC
•   Currents: 500 mA to 300 A (with MiniFlex sensor supplied)
•   Resistance: 0.3 Ω to 30 MΩ
•   Audible continuity for R ≤ 30 Ω
•   Capacitance: 400 pF to 30 mF
•   Diode test
•   No-contact voltage detection
•   600 V CAT III

Learn More

RM1,068.00

  • Availability: 0 in stock
Compare
F203 600V AC/DC TRMS Clamp Multimeter , .

1000v-new600v-newibc61010-newtrmstrue

Equipped with a fast 12-bit TRMS digital acquisition system, F203 clamps offer particularly accurate measurements whatever the signal’s type and waveform.

  • Clamping diameter: 34 mm
  • 600 A AC / 900 A DC current measurement
  • AC and DC voltage up to 1,000 V
  • Resistance and audible continuity
  • Temperature
  • Automatic AC/DC detection
  • TrueInrush current measurement
  • Hold, Min, MAX
  • RELative (ΔX) and differential (ΔX/X) measurements
  • Adapter function
  • CAT IV 600 V
Learn More

RM1,354.00

  • Availability: 0 in stock
Compare
F205 Clamp Multimeter , .

1000v-new600v-newibc61010-newtrmstrue

Equipped with a fast 12-bit TRMS digital acquisition system, F205 clamps offer particularly accurate measurements whatever the signal’s type and waveform.

  • Clamping diameter: 34 mm
  • Current: 600 A AC / 900 A DC
  • AC and DC voltage up to 1,000 V
  • Resistance and audible continuity
  • Power values (W, var, VA, PF) and harmonics (THDf, THDr)
  • “2- wire method” phase rotation
  • Automatic AC/DC detection
  • TrueInrush current measurement
  • Min, MAX, Peak+, Peak-
  • RELative (ΔX) and differential (ΔX/X) measurements
  • CAT IV 600 V
Learn More

RM1,761.00

  • Availability: 0 in stock
Compare